Analysis, support and tools
From BIM to energy model
A BIM model contains most of the geometry an energy calculation needs: rooms, storeys, facades, windows and roofs. With the right export, you do not have to draw the building again. But an architectural model is made for a different purpose, so the import must be checked, and some things must be added in the energy model.
IFC or gbXML?
IFC is the open standard format for BIM, and both Revit and ArchiCAD export it. gbXML is made specifically for energy analysis and often includes constructions, U-values and space definitions in a form that suits the calculation. If you have both, gbXML often brings more energy data, while IFC gives the most precise geometry.
What usually comes across from BIM
What comes across depends on how the model is built and exported:
- Storeys, rooms and zones with area and floor plan
- External walls as facades, with orientation
- Windows and doors with size and position
- Slabs and roofs, with roof pitch
- U-values when they are in the model or can be calculated from the material layers
What you usually need to add yourself
Architectural models often lack operating data and technical systems. Usage profiles, internal loads and set points come from NS 3031:2025 and the building category. Ventilation systems, heat recovery and energy supply must be described in the energy model. Pure discipline models without a building envelope, such as a plumbing model on its own, do not make an energy model.
Tips for the export
Include spaces (IfcSpace) in the IFC export, and make sure the spaces are closed against walls, slabs and roofs. Add U-values or material layers to the constructions where you can. Always check the import visually before you calculate: missing rooms, double walls and wrong units are the most common errors.
How Proff handles it
BIM import in Gadder Proff
Proff reads IFC2x3, IFC4 and gbXML and builds the energy model automatically, with dedicated handling of common quirks in Revit and ArchiCAD exports.
- Rooms, zones, facades by orientation, windows, doors, slabs and roofs with pitch
- U-values from the model, or calculated from the material layers when missing
- Heating systems such as boilers, heat pumps and district heating recognized where present
- Review the import in 2D and 3D before you use it
Questions and answers
Yes. Export as IFC or gbXML from Revit. Proff handles the units, default zones and missing U-values that Revit exports often have.
Sources and regulations
Always check the current version of regulations and standards before using the numbers in a project.
Read next
AI in energy calculation
AI builds the model from drawings and documents. The calculation stays standardized and traceable.
Building energy calculation software
What to require from software for energy calculation and energy simulation.
Energy calculation for architects
Early decisions on windows, form and shading, calculated while they are still cheap to change.
Spend your time on judgment, not data entry
Proff gathers available building data, reads floor plans and builds an editable model, so you can calculate everything from houses to hospitals without the detours.