Energy calculation for architects
The decisions that matter most for energy use and indoor climate are made early: the building's form, orientation, glazing and solar shading. An early-phase energy calculation shows the consequences before they are locked in, and makes it easier to meet TEK17, passive house or stricter goals.
What the architect decides
Many of the largest items in the energy calculation are architectural choices:
- Glazing ratio and placement relative to sun and views
- Solar shading and overheating in summer
- Compactness and form factor, which affect heat loss
- Constructions and thermal bridges in the details
Overheating is an architectural problem
Well-insulated buildings with large glazed areas quickly get too warm. The guidance to TEK17 section 13-4 gives recommended operative temperatures with 26 °C as the upper limit for light work. An hourly simulation shows how many hours each zone spends above the limit, and what shading or less glazing does about it.
From the BIM model, without redrawing
The architect's BIM model can be used directly as the starting point for the energy model. The calculation can then be updated as the project changes, instead of being rebuilt every time.
How Proff handles it
Gadder Proff for architects
Proff accepts the model from Revit or ArchiCAD and shows the building in 3D, so energy and indoor climate can be assessed together with the form.
- Import of IFC and gbXML from Revit and ArchiCAD, with review in 3D
- Free-floating indoor temperature and hours above 26 °C per zone
- Overheating hours per upgrade, for example solar shading
- Passive house check under NS 3700 for homes
Questions and answers
Not necessarily. Many work with an energy consultant. Software that accepts the BIM model makes the collaboration easier, because everyone works with the same geometry.
Sources and regulations
Always check the current version of regulations and standards before using the numbers in a project.
Read next
From BIM to energy model
IFC and gbXML from Revit and ArchiCAD: what comes across, and what you need to add yourself.
Peak loads and overheating in buildings
Design heating and cooling loads, and hours with too high indoor temperature.
Passive house calculation: NS 3700 and NS 3701
The criteria for passive houses and low-energy buildings, and how they are documented.
Spend your time on judgment, not data entry
Proff gathers available building data, reads floor plans and builds an editable model, so you can calculate everything from houses to hospitals without the detours.