Method
Peak loads and overheating in buildings
Energy need tells you how much a building or home uses over a year. Peak load tells you how much it needs at the coldest or warmest moment. It determines the size of the heat pump, the cooling plant and the grid connection, and it matters more and more as the power grid comes under pressure.
Design heating and cooling loads
The design heating load is calculated for design winter conditions at the site, with heat loss through constructions, thermal bridges, infiltration and ventilation. The cooling load depends on solar gains, internal loads and how much heat the building can store. The new edition of NS 3031 brings the calculation of energy and power needs into one standard, and the informative Annex W provides design climate data for all municipal centers, with duration and return period chosen by risk category.
- A correctly sized heat pump gives better efficiency and lower investment
- Lower peaks mean lower grid tariffs for commercial buildings
- Power and energy should be assessed together when choosing upgrades
Overheating and thermal comfort
Well-insulated, airtight buildings hold on to heat, including when it is not wanted. Large south- and west-facing windows, high internal loads and little solar shading quickly lead to overheating. The guidance to TEK17 section 13-4 gives recommended operative temperatures with 26 °C as the upper limit for light, medium and heavy work alike. In warm periods it can be accepted that the temperature exceeds 26 °C when the outdoor temperature is higher than the level exceeded 50 hours in a normal year. A dynamic simulation shows when and by how much each zone exceeds the limit, and what shading, ventilation or cooling does about it.
Hour by hour or quarter hour by quarter hour
Peak loads and overheating are short events. They disappear in a monthly average. That is why power needs and indoor climate must be assessed with a method that calculates hour by hour or quarter hour by quarter hour and accounts for the building storing heat.
How Proff handles it
Peak loads and indoor climate in the same model
In Proff, you calculate design loads and indoor temperature on the same model used for the energy calculation.
- Design heating and cooling loads per zone
- Free-floating indoor temperature and hours above 26 °C (TEK17 section 13-4)
- Overheating hours per upgrade, so you see what each upgrade does to the indoor climate
- Simulation of power flexibility and controls
Questions and answers
Energy need is the total over time, measured in kWh. Peak load is how much is needed at a given moment, measured in kW. A building can have a low energy need and still have high peaks.
Sources and regulations
Always check the current version of regulations and standards before using the numbers in a project.
Read next
Energy simulation for buildings and homes
Dynamic simulation hour by hour and quarter hour by quarter hour: when it gives better answers and how the result is checked.
Building energy analysis and retrofit planning
From energy audit to a prioritized retrofit plan with profitability.
U-value: calculating heat loss in components
U-values layer by layer under NS-EN ISO 6946, and the minimum requirements in TEK17.