Passive house calculation: NS 3700 and NS 3701

Passive houses have a very low heating need, achieved with good insulation, few thermal bridges, high air tightness and efficient heat recovery. In Norway, the criteria are set out in NS 3700 for residential buildings and NS 3701 for commercial buildings.

How passive houses differ from TEK17

TEK17 caps the total net energy need. The passive house standards add their own requirements for heating need and heat loss, so the building envelope, not the energy supply, delivers the low demand.

  • Requirements for the heat loss coefficient and calculated heating need
  • Minimum requirements for windows, air tightness and heat recovery
  • Requirements adjusted for building size and the local climate

NS 3700 and NS 3701

NS 3700:2013 covers residential buildings and NS 3701:2012 commercial buildings, meaning offices, schools and other non-residential buildings. The heating requirement is adjusted for building size and the annual mean temperature at the site, so a small house in a cold inland climate gets different limits than a large apartment block on the coast. Both standards also have a less strict low-energy level.

Documentation

Passive house criteria are documented with an energy calculation under NS 3031, with the additions the standards require. Because the margins are often small, it pays to calculate early and follow up when constructions, windows and ventilation systems change.

How Proff handles it

Passive house and FutureBuilt in the same calculation

Proff checks the NS 3700 passive house criteria for homes directly in the model, in addition to the TEK17 check for small houses.

  • NS 3700 for residential buildings
  • FutureBuilt criteria for plus houses and nearly zero-energy buildings
  • See which requirements are not met, and what it takes
Book a Proff demo

Questions and answers

No, TEK17 does not require passive house level. Many developers, municipalities and programs still set passive house or a similar level as a goal.

Sources and regulations

Always check the current version of regulations and standards before using the numbers in a project.