Requirements and documentation
Energy requirements in TEK17
Chapter 14 of the Norwegian building regulations sets the energy requirements for new buildings and homes and for major renovations. They consist of an energy frame for net energy need per building category, minimum requirements for each component and requirements for the energy supply. Everything is documented with a calculation under NS 3031.
The energy frame in section 14-2
The energy frame is the total net energy need a building may have per square meter of heated floor area per year. It varies by building category, because a home, a school, a nursing home and an office are used very differently. Net energy need is calculated under NS 3031:2014 with standardized input data.
Total net energy need in kWh per m² of heated floor area per year.
| Building category | Energy frame |
|---|---|
| Small house and holiday home over 150 m² | 100 + 1600 / m² heated floor area |
| Apartment block | 95 |
| Kindergarten | 135 |
| Office building | 115 |
| School building | 110 |
| University and college | 125 |
| Hospital | 225 (265) |
| Nursing home | 195 (230) |
| Hotel | 170 |
| Sports building | 145 |
| Retail building | 180 |
| Cultural building | 130 |
| Light industry and workshops | 140 (160) |
Figures in parentheses apply where heat recovery from ventilation air could spread infection or contamination. Source: Norwegian Building Authority, TEK17 section 14-2.
Minimum requirements and energy supply
On top of the energy frame, section 14-3 sets minimum U-values and air tightness, so the frame cannot be met with an efficient system alone. Under section 14-4, heating installations for fossil fuels may not be installed, and buildings with more than 1,000 m² of heated floor area must have energy-flexible heating systems covering at least 60 percent of the standardized net heating need. Residential buildings can instead meet the energy frame through a measures model with nine specific requirements.
- External wall at most 0.22, roof and floor at most 0.18, windows and doors at most 1.2 W/(m²K)
- Air leakage at most 1.5 air changes per hour at 50 Pa
- Commercial buildings also need an energy budget with realistic values
- Apartment blocks with central heating and all commercial buildings need separate meters for heating and hot water
How compliance is documented
The documentation is an energy calculation of the building as designed, with net energy need compared with the frame, a check of the minimum requirements and a description of the energy supply. When the design changes, the calculation must be updated, so it pays to work in a model where changes take effect immediately.
How Proff handles it
One model for requirements, labeling and upgrades
Proff calculates net energy need, heat loss coefficients and U-values in the same model. For small houses, the TEK17 requirements are checked automatically, including the energy frame, minimum requirements and the measures model.
- Automatic TEK17 check for small houses
- Passive house checks under NS 3700 for homes, and FutureBuilt criteria for plus houses and nearly zero-energy buildings
- Changes to the model update every result immediately
- Reports and export to PDF and Excel
Questions and answers
For a major renovation, the requirements apply to the whole building. For other work on existing buildings, they generally apply to the part being changed, and the municipality can in some cases allow exceptions under section 31-2 of the Planning and Building Act.
Sources and regulations
Always check the current version of regulations and standards before using the numbers in a project.
Read next
NS 3031:2025 and energy performance calculation
The standard every Norwegian energy calculation is built on, and what is new in the 2025 edition.
U-value: calculating heat loss in components
U-values layer by layer under NS-EN ISO 6946, and the minimum requirements in TEK17.
Passive house calculation: NS 3700 and NS 3701
The criteria for passive houses and low-energy buildings, and how they are documented.
Spend your time on judgment, not data entry
Proff gathers available building data, reads floor plans and builds an editable model, so you can calculate everything from houses to hospitals without the detours.