Requirements and documentation

Energy requirements in TEK17

Chapter 14 of the Norwegian building regulations sets the energy requirements for new buildings and homes and for major renovations. They consist of an energy frame for net energy need per building category, minimum requirements for each component and requirements for the energy supply. Everything is documented with a calculation under NS 3031.

The energy frame in section 14-2

The energy frame is the total net energy need a building may have per square meter of heated floor area per year. It varies by building category, because a home, a school, a nursing home and an office are used very differently. Net energy need is calculated under NS 3031:2014 with standardized input data.

Energy frames in TEK17 section 14-2

Total net energy need in kWh per m² of heated floor area per year.

Building categoryEnergy frame
Small house and holiday home over 150 m²100 + 1600 / m² heated floor area
Apartment block95
Kindergarten135
Office building115
School building110
University and college125
Hospital225 (265)
Nursing home195 (230)
Hotel170
Sports building145
Retail building180
Cultural building130
Light industry and workshops140 (160)

Figures in parentheses apply where heat recovery from ventilation air could spread infection or contamination. Source: Norwegian Building Authority, TEK17 section 14-2.

Minimum requirements and energy supply

On top of the energy frame, section 14-3 sets minimum U-values and air tightness, so the frame cannot be met with an efficient system alone. Under section 14-4, heating installations for fossil fuels may not be installed, and buildings with more than 1,000 m² of heated floor area must have energy-flexible heating systems covering at least 60 percent of the standardized net heating need. Residential buildings can instead meet the energy frame through a measures model with nine specific requirements.

  • External wall at most 0.22, roof and floor at most 0.18, windows and doors at most 1.2 W/(m²K)
  • Air leakage at most 1.5 air changes per hour at 50 Pa
  • Commercial buildings also need an energy budget with realistic values
  • Apartment blocks with central heating and all commercial buildings need separate meters for heating and hot water

How compliance is documented

The documentation is an energy calculation of the building as designed, with net energy need compared with the frame, a check of the minimum requirements and a description of the energy supply. When the design changes, the calculation must be updated, so it pays to work in a model where changes take effect immediately.

How Proff handles it

One model for requirements, labeling and upgrades

Proff calculates net energy need, heat loss coefficients and U-values in the same model. For small houses, the TEK17 requirements are checked automatically, including the energy frame, minimum requirements and the measures model.

  • Automatic TEK17 check for small houses
  • Passive house checks under NS 3700 for homes, and FutureBuilt criteria for plus houses and nearly zero-energy buildings
  • Changes to the model update every result immediately
  • Reports and export to PDF and Excel
Book a Proff demo

Questions and answers

For a major renovation, the requirements apply to the whole building. For other work on existing buildings, they generally apply to the part being changed, and the municipality can in some cases allow exceptions under section 31-2 of the Planning and Building Act.

Sources and regulations

Always check the current version of regulations and standards before using the numbers in a project.