Method
NS 3031:2025 and energy performance calculation
NS 3031 is the Norwegian standard for calculating the energy and power needs of buildings and homes. It sets the input data for each building category so calculations for different buildings can be compared, and it underpins both the energy requirements in TEK17 and the energy labeling scheme.
What the standard covers
NS 3031 builds on the European calculation standards and sets the national choices: climate data, operating hours, internal loads from people, lighting and equipment, hot water demand and temperature set points. With these as a shared basis, the result measures the building's properties rather than how a particular user operates it.
- Net energy need per item: space heating, ventilation heating, hot water, space and ventilation cooling, fans, pumps, lighting and technical equipment
- Delivered energy after efficiencies and energy carriers
- Heat loss coefficients for transmission, infiltration and ventilation
- Peak loads for heating and cooling
The 2014 and 2025 editions
TEK17 section 14-2 still refers to NS 3031:2014 for documenting the energy frames. A new edition in 2025 brings the calculation of energy and power needs into one standard, and Enova refers to the new edition in the energy labeling scheme that applies from 2026. Always check which edition the regulation or program you are documenting against requires.
The 13 building categories
The standard divides buildings into small houses, apartment blocks, kindergartens, offices, schools, universities and colleges, hospitals, nursing homes, hotels, sports buildings, retail buildings, cultural buildings, and light industry and workshops. The category drives the input data, so a building with several functions should be split into zones with their own categories.
How Proff handles it
NS 3031:2025 built into the calculation
Proff uses the NS 3031:2025 input data for all 13 building categories and calculates dynamically under NS-EN ISO 52016-1.
- Energy need, delivered energy and energy grade A to G per building
- Heat pumps, boilers, district heating, solar panels and batteries in the energy supply
- Hourly climate data for each municipality, from the 1991 to 2020 normal period
- Design outdoor temperature from NS 3031:2025
- The AINA AI assistant looks up NS 3031 and shows the table and page
Questions and answers
It depends on what you are documenting. TEK17 section 14-2 refers to NS 3031:2014, while the energy labeling scheme from 2026 refers to the new 2025 edition. Always check the requirement in the regulation or program you are delivering to.
Sources and regulations
Always check the current version of regulations and standards before using the numbers in a project.
Read next
Energy simulation for buildings and homes
Dynamic simulation hour by hour and quarter hour by quarter hour: when it gives better answers and how the result is checked.
Energy requirements in TEK17
Energy frames per building category, minimum requirements and how compliance is documented.
Energy labels for commercial buildings
When commercial buildings need an energy certificate, who may issue it and what changed in 2026.
Spend your time on judgment, not data entry