NS 3031:2025 and energy performance calculation

NS 3031 is the Norwegian standard for calculating the energy and power needs of buildings and homes. It sets the input data for each building category so calculations for different buildings can be compared, and it underpins both the energy requirements in TEK17 and the energy labeling scheme.

What the standard covers

NS 3031 builds on the European calculation standards and sets the national choices: climate data, operating hours, internal loads from people, lighting and equipment, hot water demand and temperature set points. With these as a shared basis, the result measures the building's properties rather than how a particular user operates it.

  • Net energy need per item: space heating, ventilation heating, hot water, space and ventilation cooling, fans, pumps, lighting and technical equipment
  • Delivered energy after efficiencies and energy carriers
  • Heat loss coefficients for transmission, infiltration and ventilation
  • Peak loads for heating and cooling

The 2014 and 2025 editions

TEK17 section 14-2 still refers to NS 3031:2014 for documenting the energy frames. A new edition in 2025 brings the calculation of energy and power needs into one standard, and Enova refers to the new edition in the energy labeling scheme that applies from 2026. Always check which edition the regulation or program you are documenting against requires.

The 13 building categories

The standard divides buildings into small houses, apartment blocks, kindergartens, offices, schools, universities and colleges, hospitals, nursing homes, hotels, sports buildings, retail buildings, cultural buildings, and light industry and workshops. The category drives the input data, so a building with several functions should be split into zones with their own categories.

How Proff handles it

NS 3031:2025 built into the calculation

Proff uses the NS 3031:2025 input data for all 13 building categories and calculates dynamically under NS-EN ISO 52016-1.

  • Energy need, delivered energy and energy grade A to G per building
  • Heat pumps, boilers, district heating, solar panels and batteries in the energy supply
  • Hourly climate data for each municipality, from the 1991 to 2020 normal period
  • Design outdoor temperature from NS 3031:2025
  • The AINA AI assistant looks up NS 3031 and shows the table and page
Book a Proff demo

Questions and answers

It depends on what you are documenting. TEK17 section 14-2 refers to NS 3031:2014, while the energy labeling scheme from 2026 refers to the new 2025 edition. Always check the requirement in the regulation or program you are delivering to.

Sources and regulations

Always check the current version of regulations and standards before using the numbers in a project.