The energy performance certificate shows a building's energy grade from A to G and recommended upgrades. In Norway, energy labeling is mandatory when a commercial or other non-residential building is sold or leased, and it must be done by an expert. Amendments to the energy labeling regulation apply from January 1, 2026.

When is a certificate required?

The owner is responsible for the energy label. The certificate is valid for ten years, but must be renewed if the building changes in a way that can affect the grade. Buildings with more than 500 m² of heated floor area that are frequently visited by the public must also display a summary of the certificate.

  • When a commercial building is sold or leased
  • When a new building or major renovation is completed
  • When more than 250 m² of the heated floor area is used by public authorities and the building is often visited by the public

Who may label commercial buildings?

Commercial buildings must be labeled by an expert who meets the competence requirements in the regulation. That can be an employee of the owner with the right qualifications, or an external energy consultant. The owner is responsible for making sure the requirements are met and must be able to document it.

Amended regulation from 2026

The amendments to the energy labeling regulation apply from January 1, 2026, and the calculation must now follow NS 3031:2025. The energy grade is a single letter from A to G, set by the calculated weighted delivered energy per square meter of heated floor area (sections 10a and 10b). The best grade cannot be given without an airtightness test (section 11). The certificate is issued in Enova's energy labeling system, where data from the calculation software is submitted and checked.

How Proff handles it

From model to energy certificate without double work

Proff is connected to Enova's energy labeling system. The calculation and the certificate data are created in the same model, and the data goes straight to Enova.

  • Energy grade A to G under the energy labeling regulation
  • Direct submission to Enova's energy labeling system, or export in Enova's format
  • Checks before submission, including the measured energy use requirement for commercial buildings
  • Recommended upgrades with calculated effect and profitability
Book a Proff demo

Questions and answers

Yes. The Norwegian regulations use a term that covers every building that is not a home, including schools, hospitals and public buildings, not just offices, shops and hotels. The energy labeling rules for commercial buildings apply to all of them.

Sources and regulations

Always check the current version of regulations and standards before using the numbers in a project.

Read next

Spend your time on judgment, not data entry

Proff gathers available building data, reads floor plans and builds an editable model, so you can calculate everything from houses to hospitals without the detours.