Requirements and documentation
New Norwegian energy labeling rules 2026
Changes to the Norwegian energy labeling regulation for buildings apply from January 1, 2026. They were adopted on April 2, 2025, and the switch to NS 3031:2025 took effect on the same day as the rest. The label looks different, the grade is calculated in a new way, and the calculation follows a new standard.
A new grade scale
The energy grade is now based on weighted delivered energy per m² of heated floor area, with a separate scale for each building category. The limit for A is 15 percent below the TEK17 level, so a building that just meets TEK17 gets B. The scale is set so the 15 percent least efficient buildings in each category get G, and C to G have equal steps.
- Weighting factors: electricity 1, district heating, district cooling and bioenergy 0.45, other energy carriers 1, and exported energy 0
- The grade is calculated in a normalized climate, with Oslo as the reference
- The certificate also shows delivered energy in the local climate, without weighting
Upper limit for each grade in kWh of weighted delivered energy per m² of heated floor area per year. G has no upper limit.
| Category | A | B | C | D | E | F |
|---|---|---|---|---|---|---|
| Office building | 75 | 90 | 140 | 190 | 235 | 285 |
| Retail building | 110 | 130 | 200 | 265 | 330 | 395 |
| School building | 70 | 85 | 150 | 210 | 275 | 340 |
Source: Enova, basis for the new energy grade scale. The scale for all 13 categories, including small houses and apartment blocks where the limits depend on floor area, is available from Enova.
One letter, no heating grade
The colored heating grade has been removed. The label is now a single letter from A to G, and the weighting factors take over the role of the heating grade: they reward renewable heat such as district heating and bioenergy.
NS 3031:2025 and requirements for calculation software
The calculation must follow NS 3031:2025. The certificate is issued in Enova's energy labeling system. Other calculation software can be used when it calculates under NS 3031:2025, can transfer data to the labeling system and is validated as the standard requires. Enova's own tool can only be used for homes, so non-residential buildings must be labeled with external calculation software.
What has not changed
The certificate is still valid for up to ten years. Non-residential buildings in operation must still report measured energy use for the last three years, and the competence requirements for whoever issues the label are the same. Certificates issued before 2026 remain valid until they expire. The change in the regulation does not by itself require a new certificate.
How Proff handles it
Energy labeling after 2026 with Gadder Proff
Proff calculates under NS 3031:2025 and is one of three applications Enova has approved for direct registration of energy labels.
- Energy grade A to G on the new scale
- Submission straight to Enova's energy labeling system
- Checks of the information before submission, including measured energy use for non-residential buildings
- For homes and every type of non-residential building
Questions and answers
No, not for that reason alone. Certificates issued before 2026 remain valid until they expire. But Enova's investment support has required a certificate dated January 1, 2026 or later.
Sources and regulations
Always check the current version of regulations and standards before using the numbers in a project.
Read next
Energy performance certificates in Norway
When you need an energy certificate, what it costs and who can issue it, for homes and commercial buildings.
Energy labels for commercial buildings
When commercial buildings need an energy certificate, who may issue it and what changed in 2026.
NS 3031:2025 and energy performance calculation
The standard every Norwegian energy calculation is built on, and what is new in the 2025 edition.
Spend your time on judgment, not data entry